Home/Products/Insulating Rubber Mats/IEC 61111 Standard Insulating Mat 10 kV / 35 kV
IEC 61111 Standard Insulating Mat 10 kV / 35 kV image 1
Factory DirectIEC 61111ASTM D178

IEC 61111 Standard Insulating Mat 10 kV / 35 kV

Anti-slip switchroom insulating mat complying with IEC 61111, tested 100% before shipment.

MOQ
10 m²
Supply Type
OEM / ODM / Buyer Label

Final quotation depends on specification, quantity and destination — request a quote for exact pricing.

Type
Rubber
Rated Voltage
5kV, 10kV, 35kV
Model Number
3MM, 5MM, 10MM
Place of Origin
Hebei, China
Brand Name
DLEC61111 Standard
Product Name
High Voltage Insulating Rubber Mat
Watch

IEC 61111 Standard Insulating Mat 10 kV / 35 kV in the workshop

Product video · 00:40 — press play to load it.

Product Attributes

TypeRubber
Rated Voltage5kV, 10kV, 35kV
Model Number3MM, 5MM, 10MM
Place of OriginHebei, China
Brand NameDLEC61111 Standard
Product NameHigh Voltage Insulating Rubber Mat
MaterialNatural rubber
Surface PatternFine ribbed
Color OptionsRed, black, green
Width1m / 1.2m / 1.5m (customizable)
ApplicationDedicated power distribution rooms
Working Temperature-25°C to +70°C
Keywordsinsulating rubber mat, IEC 61111 mat, high voltage mat
Hardness65 ± 5 Shore A

Description

IEC 61111 Standard Insulating Mat (10kV / 35kV) — electrical safety rubber mat for substations and power distribution rooms. Product Highlights: - Dielectric strength: manufactured to IEC 61111; every batch is high-voltage tested before shipment. - Anti-slip and wear-resistant: textured surface design prevents slips in industrial environments. - Flame-retardant: self-extinguishing material enhances fire safety in power rooms. - Eco-friendly, low odor: made from premium rubber compound with minimal chemical odor, suitable for indoor use. - Acid and alkali resistant: durable in harsh chemical or oil-contaminated environments. Standards & quality: manufactured strictly to IEC 61111 (international) or ASTM D178 (US); every batch passes high-voltage withstand testing before shipment; internal test reports or third-party testing (SGS/TUV) available. Voltage rating and class: thickness does not set the voltage rating. IEC 61111 assigns Class 0-4 by maximum service voltage, and the mat thickness has to fall inside that class's permitted range. Tell us the maximum service voltage of the installation and we will confirm the class on the certificate. Durability: made from virgin rubber — no strong toxic chemical odor; safe for long-term use in enclosed distribution rooms. Contains anti-aging and anti-UV additives; service life 10+ years under normal indoor conditions. Customization: standard colors black/red/green; rolls cut to your specific length and width (width up to 2m); multiple surface textures (fine rib, wide rib, diamond pattern) for wet-condition traction. Packaging: each roll wrapped in moisture-proof film, then packed in woven bags or on fumigated wooden pallets to prevent deformation or scratching during sea freight.
IEC 61111 Standard Insulating Mat 10 kV / 35 kV detail 1IEC 61111 Standard Insulating Mat 10 kV / 35 kV detail 2IEC 61111 Standard Insulating Mat 10 kV / 35 kV detail 3IEC 61111 Standard Insulating Mat 10 kV / 35 kV detail 4IEC 61111 Standard Insulating Mat 10 kV / 35 kV detail 5IEC 61111 Standard Insulating Mat 10 kV / 35 kV detail 6
Request a quote

Ask about IEC 61111 Standard Insulating Mat 10 kV / 35 kV

Send the quantity, the voltage class or size, and the standards your project calls for. Our export engineers reply within 24 hours with a quotation, lead time, and the test certificates available with the order.

  • Quotation and lead time within 24 hours, Mon–Sat
  • Test certificates supplied with the order
  • Factory direct — HEBEI YUJINHONG TECHNOLOGY CO., LTD.

Request a quote for this product

Goes straight to our export engineers with the model already noted — mat-standard

Reply within 24 hours, Mon–SatOr chat on WhatsApp →
Technical guides

Still deciding? Read the engineering guide

Background on how this product's class, dimensions and test requirements are determined.

Insulation & Standards · 6 min read

Type II Matting: What IIA, IIB and IIC Actually Test

IIA, IIB and IIC are three separate ASTM D178 tests, not three grades. Ozone with no visible effect, flame with 12.7 mm of char after 30 seconds, oil with 4 % volume swell. Pick the letter from the exposure, not from the room name.

Read the guide
Insulation & Standards · 6 min read

IEC 61111 Matting Classes 0–4: The Ladder, the Windows and the Yearly Test

Class sets the voltage band and the thickness window, but it is the yearly test that separates the classes commercially: Class 0 needs a visual check, Class 4 goes back on a 40 kV set.

Read the guide
Insulation & Standards · 7 min read

IEC 61111 vs ASTM D178: Which Insulating Mat Standard Applies to Your Project?

The two standards share one voltage ladder and disagree on thickness — 3 mm versus 6.4 mm at the same class. The class-by-class comparison, the Type and Category systems, and how to write a spec that survives inspection.

Read the guide
Insulation & Standards · 6 min read

EN 50321-1 Insulating Boots: The 2018 Revision Moved the Class Ladder

The 2018 revision moved insulating footwear from two classes to six, but the DC ladder still stops at Class 2. The class table, the antistatic boundary, and the lines that belong on the order.

Read the guide
Insulation & Standards · 6 min read

Mat Storage vs In-Service Temperature: Why the Two Ranges Differ

One manufacturer's IEC 61111 matting is published at −40 °C to +55 °C working and +10 °C to +21 °C in storage. Two ranges, two different jobs — and the storage one is the one nobody reads.

Read the guide
Insulation & Standards · 6 min read

Which Edition of IEC 61111 Applies to Your Matting Order — and Which Regional Adoption

A PO that says "IEC 61111" leaves two things open: which edition, and which regional adoption. IEC 61111:2026 has cancelled the 2009 edition, and CAN/ULC-61111-10 is a modified adoption, not a reprint.

Read the guide
Insulation & Standards · 8 min read

Insulating Mat Thickness and Voltage: The Complete Reference Table

One reference for every figure behind insulating mat selection: IEC 61111 Class 0-4 voltages and proof test levels, the thickness window for each class, the ASTM D178 ladder, colour codes and retest voltages.

Read the guide
Insulation & Standards · 9 min read

How to Choose Insulating Rubber Mat Thickness: A Voltage-Based Selection Guide

Thickness does not set a mat's voltage rating — the class does. A guide to the IEC 61111 Class 0–4 table, the selection rule, and how to write a specification that survives an audit.

Read the guide
FAQ

Frequently asked questions

Answers below are taken directly from this product's recorded specification, packaging and delivery data.

Which standards and certifications does this product comply with?
IEC 61111 Standard Insulating Mat 10 kV / 35 kV is supplied under IEC 61111 and ASTM D178.
What is the minimum order quantity (MOQ)?
The minimum order quantity for this product is 10 m².
What is the lead time?
Lead time: 7-30 days, depending on order quantity.
Which port is the product shipped from?
Shipments are loaded at Tianjin.
What is the monthly supply ability?
Supply ability: 90,000 m²/month.
What are the main technical specifications?
Voltage Class: 5 / 10 / 35 kV; Standard: IEC 61111.
How is the product packed for shipment?
Selling unit: Single item; Single package size: 100X100X1 cm; Single gross weight: 20.0 kg
Which payment terms are accepted?
Accepted payment terms: FOB.
Can this product be customized?
Customization: Custom roll sizes
Ask a technical question
Start Your Project

Let's build your power infrastructure together

Send us your specifications — insulating mats, gloves, voltage detectors, grounding systems or safety tooling projects. Our engineers respond within 24 hours with technical recommendations and pricing.