IEC 61111 Standard Insulating Mat 10 kV / 35 kV
Anti-slip switchroom insulating mat complying with IEC 61111, tested 100% before shipment.
Final quotation depends on specification, quantity and destination — request a quote for exact pricing.
- Type
- Rubber
- Rated Voltage
- 5kV, 10kV, 35kV
- Model Number
- 3MM, 5MM, 10MM
- Place of Origin
- Hebei, China
- Brand Name
- DLEC61111 Standard
- Product Name
- High Voltage Insulating Rubber Mat
IEC 61111 Standard Insulating Mat 10 kV / 35 kV in the workshop
Product video · 00:40 — press play to load it.
Product Attributes
| Type | Rubber |
| Rated Voltage | 5kV, 10kV, 35kV |
| Model Number | 3MM, 5MM, 10MM |
| Place of Origin | Hebei, China |
| Brand Name | DLEC61111 Standard |
| Product Name | High Voltage Insulating Rubber Mat |
| Material | Natural rubber |
| Surface Pattern | Fine ribbed |
| Color Options | Red, black, green |
| Width | 1m / 1.2m / 1.5m (customizable) |
| Application | Dedicated power distribution rooms |
| Working Temperature | -25°C to +70°C |
| Keywords | insulating rubber mat, IEC 61111 mat, high voltage mat |
| Hardness | 65 ± 5 Shore A |
Description






Ask about IEC 61111 Standard Insulating Mat 10 kV / 35 kV
Send the quantity, the voltage class or size, and the standards your project calls for. Our export engineers reply within 24 hours with a quotation, lead time, and the test certificates available with the order.
- Quotation and lead time within 24 hours, Mon–Sat
- Test certificates supplied with the order
- Factory direct — HEBEI YUJINHONG TECHNOLOGY CO., LTD.
Request a quote for this product
Goes straight to our export engineers with the model already noted — mat-standard
Still deciding? Read the engineering guide
Background on how this product's class, dimensions and test requirements are determined.
Type II Matting: What IIA, IIB and IIC Actually Test
IIA, IIB and IIC are three separate ASTM D178 tests, not three grades. Ozone with no visible effect, flame with 12.7 mm of char after 30 seconds, oil with 4 % volume swell. Pick the letter from the exposure, not from the room name.
Read the guide Insulation & Standards · 6 min readIEC 61111 Matting Classes 0–4: The Ladder, the Windows and the Yearly Test
Class sets the voltage band and the thickness window, but it is the yearly test that separates the classes commercially: Class 0 needs a visual check, Class 4 goes back on a 40 kV set.
Read the guide Insulation & Standards · 7 min readIEC 61111 vs ASTM D178: Which Insulating Mat Standard Applies to Your Project?
The two standards share one voltage ladder and disagree on thickness — 3 mm versus 6.4 mm at the same class. The class-by-class comparison, the Type and Category systems, and how to write a spec that survives inspection.
Read the guide Insulation & Standards · 6 min readEN 50321-1 Insulating Boots: The 2018 Revision Moved the Class Ladder
The 2018 revision moved insulating footwear from two classes to six, but the DC ladder still stops at Class 2. The class table, the antistatic boundary, and the lines that belong on the order.
Read the guide Insulation & Standards · 6 min readMat Storage vs In-Service Temperature: Why the Two Ranges Differ
One manufacturer's IEC 61111 matting is published at −40 °C to +55 °C working and +10 °C to +21 °C in storage. Two ranges, two different jobs — and the storage one is the one nobody reads.
Read the guide Insulation & Standards · 6 min readWhich Edition of IEC 61111 Applies to Your Matting Order — and Which Regional Adoption
A PO that says "IEC 61111" leaves two things open: which edition, and which regional adoption. IEC 61111:2026 has cancelled the 2009 edition, and CAN/ULC-61111-10 is a modified adoption, not a reprint.
Read the guide Insulation & Standards · 8 min readInsulating Mat Thickness and Voltage: The Complete Reference Table
One reference for every figure behind insulating mat selection: IEC 61111 Class 0-4 voltages and proof test levels, the thickness window for each class, the ASTM D178 ladder, colour codes and retest voltages.
Read the guide Insulation & Standards · 9 min readHow to Choose Insulating Rubber Mat Thickness: A Voltage-Based Selection Guide
Thickness does not set a mat's voltage rating — the class does. A guide to the IEC 61111 Class 0–4 table, the selection rule, and how to write a specification that survives an audit.
Read the guideFrequently asked questions
Answers below are taken directly from this product's recorded specification, packaging and delivery data.
- Which standards and certifications does this product comply with?
- IEC 61111 Standard Insulating Mat 10 kV / 35 kV is supplied under IEC 61111 and ASTM D178.
- What is the minimum order quantity (MOQ)?
- The minimum order quantity for this product is 10 m².
- What is the lead time?
- Lead time: 7-30 days, depending on order quantity.
- Which port is the product shipped from?
- Shipments are loaded at Tianjin.
- What is the monthly supply ability?
- Supply ability: 90,000 m²/month.
- What are the main technical specifications?
- Voltage Class: 5 / 10 / 35 kV; Standard: IEC 61111.
- How is the product packed for shipment?
- Selling unit: Single item; Single package size: 100X100X1 cm; Single gross weight: 20.0 kg
- Which payment terms are accepted?
- Accepted payment terms: FOB.
- Can this product be customized?
- Customization: Custom roll sizes
Let's build your power infrastructure together