The grounding range is two lists now: eight portable sets in their own product family, and the conductors, clamps, storage and arresters they are built from on a renamed page.
The grounding and earthing range was one long list until 17 November. Now it is two. Eight portable products — substation sets, the 27.5 kV railway catenary set, and the personal safety leads — moved into their own product family at Earthing Kits & Grounding Sets. The page they came from was renamed to Grounding Conductors, Rail Clamps & Surge Arresters, which is what it now holds: seven items, none of them a complete set.
That split follows how the equipment is actually bought. A complete set is quoted from the duty at the point of work — prospective fault current, clearing time, and the conductor the clamps have to land on. A conductor, a rail clamp, a winding rack or a discharge rod is bought as a part, often to extend a set that already exists. Both in one list meant scrolling past copper wire sold by the metre to reach the sets, and it meant the sets kept getting read as accessories.
Here is what sits in the new family: a three-phase short-circuit earthing set with earth rod rated across 0.4 kV to 500 kV; 110 kV and 110 kV / 220 kV substation arrangements; a 110 kV portable kit built to IEC 61230; a 10 kV cable set for distribution; the 27.5 kV catenary set with a gooseneck hook on a three-section operating rod; a 0.4 kV / 10 kV personal safety grounding lead; a 35–1000 kV personal security earthing wire; and a portable earthing wire set with spiral and alligator clamps in 3 m to 15 m lengths.
Keeping the parts as their own family is not tidying for its own sake. IEC 61230:2008 allows the components to be bought separately against the standard, so a clamp, a length of cable or an earth point can be ordered on its own when a set is being extended rather than replaced. That only works if you can see parts and sets as two families that link to each other, instead of one undifferentiated list.
One thing the split does not change: the standard still gives no rated voltage. Performance is based on the electro-dynamic and electro-thermal effects during a short circuit, and the withstand capability is the rated current, rated time and peak factor. Installation voltage decides the insulation and the geometry, not the rating. So a requisition that says "33 kV grounding set" and nothing else still cannot be quoted for cross-section — put the fault current and the clearing time next to it. Both families are live now, and [email protected] reaches the same desk either way.
Need this confirmed against your own installation?
Send us the network voltage, the standard you are specifying against and the ambient conditions. Our engineers will confirm the class, thickness and test report, and reply with lead time.
Ask a technical question