The operating rod page lists six single-section lengths and four two-section builds. The 4 m is the one buyers ask about. What a two-section build buys, what it costs, and the four lines that settle the order.
The operating rod page lists six single-section lengths and four two-section builds, and the 4 m two-section is the one buyers ask about. Two things about it are worth knowing before the enquiry goes out.
A single section is one tube. That makes it the stiffest option per metre, and on a rod that has to hold a switch or a fuse cutout at arm's length, stiffness is the whole job. What it does not do is travel well: a long single tube ships in a carton the length of the rod, which is fine for a substation store and awkward for a van. The two-section build splits it. The 4 m two-section packs into a carton measuring 268 × 20 × 20 cm at 4.0 kg, so one person carries it and it goes in the back of a pickup.
What you give up is continuity. Two sections mean two joints, and each joint is a place where the tube has to stay straight under load. That is the number a datasheet cannot give you: at full extension, the question is not how long the rod is, it is whether it still behaves like a rod. One that flexes at full reach is not usable for switching on a live conductor, however good the insulation is.
So length is the last decision, not the first. Four lines settle it:
- The working height you actually have to reach — that sets the length, not the other way round.
- The head: a fuse puller for cutout work, a universal head for load break switch operation.
- Whether the rod travels between sites or lives in one store, which is what decides single versus two-section.
- The voltage class your switching procedure names. Length does not substitute for it.
All builds are epoxy resin glass fibre with an anti-slip non-conductive surface, supplied in shotgun and telescopic types under IEC 60832, minimum order one piece. Six single-section lengths (1.38 m to 2.5 m) and four two-section builds (2.5 m to 4.0 m) are quoted off the same page, so the size you need is a line on the enquiry rather than a special request.
Tell us the working height, the head and the class, and we will confirm the build against what we would ship: Telescopic & Shotgun Type Insulated Operating Rod. Mail [email protected].
Need this confirmed against your own installation?
Send us the network voltage, the standard you are specifying against and the ambient conditions. Our engineers will confirm the class, thickness and test report, and reply with lead time.
Ask a technical question