High Voltage Insulated Operating Rod, Telescopic
Telescopic fibreglass-reinforced epoxy operating rod for live-line working and distribution line maintenance. Linked and telescopic types from 10 kV to 500 kV, with fluorescent tip, non-slip grip and locking joints.
Final quotation depends on specification, quantity and destination — request a quote for exact pricing.
- Application
- Live-line working, distribution line maintenance
- Material
- Fibreglass-reinforced epoxy resin
- Types
- Linked type and telescopic type
- Voltage range
- 10 kV to 500 kV
- Working length
- 2 m to 10 m (2-5 sections)
- Grip
- Non-slip rubber handle
Product Attributes
| Application | Live-line working, distribution line maintenance |
| Material | Fibreglass-reinforced epoxy resin |
| Types | Linked type and telescopic type |
| Voltage range | 10 kV to 500 kV |
| Working length | 2 m to 10 m (2-5 sections) |
| Grip | Non-slip rubber handle |
| Tip | Fluorescent green, high visibility |
| Place of Origin | Hebei, China |
Description





Ask about High Voltage Insulated Operating Rod, Telescopic
Send the quantity, the voltage class or size, and the standards your project calls for. Our export engineers reply within 24 hours with a quotation, lead time, and the test certificates available with the order.
- Quotation and lead time within 24 hours, Mon–Sat
- Test certificates supplied with the order
- Factory direct — HEBEI YUJINHONG TECHNOLOGY CO., LTD.
Request a quote for this product
Goes straight to our export engineers with the model already noted — insulated-operating-rod-telescopic
Related Products
View all Insulating Tools, Ladders & DetectorsStill deciding? Read the engineering guide
Background on how this product's class, dimensions and test requirements are determined.
Specifying a Voltage Detector: What IEC 61243-1 Covers, and What Your Switching Rules Cover
Two different questions get answered with the same three words. What the IEC 61243-1 text actually covers, why the pre-use proof test comes from your operating rules rather than the standard, and how to write a specification that keeps the two clauses apart.
Read the guide Insulation & Standards · 5 min readInsulating Ladders for Live Working: What IEC 61478 Is, and What It Is Not
IEC 61478 covers ladders of insulating material for live working — and its scope stops there. What the scope wording admits, why mobile insulating platforms are outside it, and what to put in the tender instead.
Read the guideFrequently asked questions
Answers below are taken directly from this product's recorded specification, packaging and delivery data.
- What is the minimum order quantity (MOQ)?
- The minimum order quantity for this product is 5 units.
- What is the lead time?
- Lead time: 15 days for 1-5 units; 30 days for 6-100 units.
- What are the main technical specifications?
- Material: Fibreglass-reinforced epoxy resin; Voltage range: 10 kV / 35 kV / 110 kV / 220 kV / 500 kV.
- How is the product packed for shipment?
- 215 x 8 x 8 cm, gross weight 6.1 kg
Pultruded tube, matched sections, tested before packing
The fiberglass-reinforced epoxy tube is pultruded on our own line, then cut, squared and matched into telescopic or linked sets. Every batch goes through insulation withstand testing before it is released for packing.



Process — how it is made
- Fiberglass-reinforced epoxy tube pultruded on our own line, which sets the wall thickness and resin content of the insulating barrier.
- Sections cut and squared, then matched into telescopic or linked sets — 2 to 5 sections for working lengths from 2 m to 10 m, 10 kV to 500 kV.
- Locking joints fitted and tightened so the threaded joint stays firm in service, without shaking or working loose.
- Fluorescent green tip section fitted for identification and night-time operation.
- Non-slip rubber grip and end cap fitted, then the rod is cleaned and checked before packing.
Inspection — how it is checked
- Insulation withstand test on every batch, recorded against the production order.
- Section-fit check: the sections are assembled and extended to the working length to confirm that the joints lock and the rod runs true.
- Surface inspection along the whole tube — no cracks, voids or exposed fiber on the surface that provides the insulation.
- Grip and end-cap check for adhesion and fit, because the handle is the part the operator relies on.
- Final check and packing at 215 x 8 x 8 cm, 6.1 kg gross.
Capacity and delivery for this line
- This product: minimum order 5 units, with a lead time of 15 days for 1–5 units and 30 days for 6–100 units.
- Company: 525 employees, 7 dedicated production lines and 80,000 m² of manufacturing buildings inside a 1,200,000 m² industrial park in Shijiazhuang, Hebei.
- Manufacturing electrical safety equipment since 1996, with 5000+ projects delivered to 60+ countries.
- Industrial park (site area)
- 1,200,000 m²
- Manufacturing buildings (floor area)
- 80,000 m²
- Dedicated production lines
- 7
- Employees
- 525
- Countries served
- 60+
- Projects delivered
- 5000+
Let's build your power infrastructure together
Send us your specifications — insulating mats, gloves, voltage detectors, grounding systems or safety tooling projects. Our engineers respond within 24 hours with technical recommendations and pricing.