High Voltage Insulated Personal Rescue Hook
Insulated rescue hook for releasing a casualty from a live conductor without direct contact. Epoxy resin pole with threaded metal couplings, a curved detachable hook and a non-slip insulated rubber grip.
Final quotation depends on specification, quantity and destination — request a quote for exact pricing.
- Application
- Power plants, substations, factories, construction sites
- Material
- Epoxy resin
- Type
- Insulated rescue hook
- Pole coupling
- Threaded metal coupling, sections assembled freely
- Hook
- Curved, detachable and interchangeable
- Place of Origin
- Hebei, China
Product Attributes
| Application | Power plants, substations, factories, construction sites |
| Material | Epoxy resin |
| Type | Insulated rescue hook |
| Pole coupling | Threaded metal coupling, sections assembled freely |
| Hook | Curved, detachable and interchangeable |
| Place of Origin | Hebei, China |
Description





Ask about High Voltage Insulated Personal Rescue Hook
Send the quantity, the voltage class or size, and the standards your project calls for. Our export engineers reply within 24 hours with a quotation, lead time, and the test certificates available with the order.
- Quotation and lead time within 24 hours, Mon–Sat
- Test certificates supplied with the order
- Factory direct — HEBEI YUJINHONG TECHNOLOGY CO., LTD.
Request a quote for this product
Goes straight to our export engineers with the model already noted — rescue-hook-insulated
Related Products
View all Insulating Tools, Ladders & Detectors
High Voltage Insulated Operating Rod, Telescopic
View Details
Insulated Fibreglass (FRP) Step Stool & Work Platform
View Details
Telescopic & Shotgun Type Insulated Operating Rod with Fuse Puller (IEC 60832)
View Details
Vehicle-Mounted Manned Elevating Rotating Insulated Platform NKPD-ZC-100KG
View DetailsStill deciding? Read the engineering guide
Background on how this product's class, dimensions and test requirements are determined.
Specifying a Voltage Detector: What IEC 61243-1 Covers, and What Your Switching Rules Cover
Two different questions get answered with the same three words. What the IEC 61243-1 text actually covers, why the pre-use proof test comes from your operating rules rather than the standard, and how to write a specification that keeps the two clauses apart.
Read the guide Insulation & Standards · 5 min readInsulating Ladders for Live Working: What IEC 61478 Is, and What It Is Not
IEC 61478 covers ladders of insulating material for live working — and its scope stops there. What the scope wording admits, why mobile insulating platforms are outside it, and what to put in the tender instead.
Read the guideFrequently asked questions
Answers below are taken directly from this product's recorded specification, packaging and delivery data.
- What is the minimum order quantity (MOQ)?
- The minimum order quantity for this product is 2 pieces.
- What is the lead time?
- Lead time: 15 days for 1-2 pieces; 30 days for 3-100 pieces.
- How is the product packed for shipment?
- 152 x 10 x 10 cm, gross weight 2.0 kg
- Can this product be customized?
- Customisation: Pole length and diameter can be customised
One site, from the insulated pole to the hook
The insulated pole, the threaded couplings and the detachable hook are all produced or finished here, so the two halves of the tool are matched to each other before they are packed together.



Process — how it is made
- Epoxy resin pole pultruded in-house, then cut and squared to the ordered length.
- Threaded metal couplings machined on site and matched to the pole ends, so sections assemble freely and stay aligned.
- Curved hook produced as a detachable part, so a different hook size or shape can be fitted to the same pole.
- Thickened rubber grip and insulating barrier skirt bonded to the pole, then checked by hand for thickness and adhesion.
- Customized pole lengths and diameters finished to the buyer specification, with the section count set by the order.
Inspection — how it is checked
- Incoming material check on resin, reinforcement and bought-in metal parts before they are released to the line.
- In-process checks at the cutting, coupling and grip stations, recorded against the production order.
- Insulation withstand testing before shipment, with third-party testing supported on request.
- Hook fit check: the detachable hook is fitted, removed and refitted to confirm that it seats fully and locks in place.
- Assembled-length check: sections are joined and the assembled pole is inspected for straightness and joint tightness.
Capacity and delivery for this line
- This product: minimum order 2 pieces, with a lead time of 15 days for 1–2 pieces and 30 days for 3–100 pieces.
- Company: 525 employees, 7 dedicated production lines and 80,000 m² of manufacturing buildings inside a 1,200,000 m² industrial park in Shijiazhuang, Hebei.
- Manufacturing electrical safety equipment since 1996, with 5000+ projects delivered to 60+ countries.
- Industrial park (site area)
- 1,200,000 m²
- Manufacturing buildings (floor area)
- 80,000 m²
- Dedicated production lines
- 7
- Employees
- 525
- Countries served
- 60+
- Projects delivered
- 5000+
Let's build your power infrastructure together
Send us your specifications — insulating mats, gloves, voltage detectors, grounding systems or safety tooling projects. Our engineers respond within 24 hours with technical recommendations and pricing.